Lsk Series Vertical Type Horizontal Type Oil-Fired Boiler Waste Burner
Product Description
Lsk Series Vertical Type Horizontal Type Oil-Fired Boiler Waste Burner
LSK Series Vertical Type Oil-fired Boiler
Marine Boiler
The design and arrangement of both the types is just the opposite. In water tube boilers, the feed water passes through the tubes and the hot gases are made to pass over them, while in fire tube boilers, the hot gases passes through the tubes and the feed water surrounds them.
1) LSK Series Vertical Type Oil-fired Boiler
type and specs | rated steam capacity(t/h) | working pressure(Mpa) | dimensions(mm) | weight(kg) | ||
H | D | D1 | ||||
LSK0.5-0.7 | 0.5 | 0.7 | 2900 | 1100 | 250 | 2500 |
LSK0.7-0.7 | 0.7 | 0.7 | 3400 | 1200 | 250 | 2900 |
LSK1.0-0.7 | 1 | 0.7 | 3800 | 1250 | 300 | 4000 |
LSK1.5-0.7 | 1.5 | 0.7 | 3700 | 1530 | 300 | 5300 |
LSK2.0-0.7 | 2 | 0.7 | 4100 | 1600 | 350 | 6200 |
LSK3.0-0.7 | 3 | 0.7 | 4700 | 1800 | 350 | 9000 |
LSK4.0-0.7 | 4 | 0.7 | 5100 | 2000 | 400 | 13000 |
LSK5.0-0.7 | 5 | 0.7 | 5300 | 2230 | 500 | 16000 |
LSK6.0-0.7 | 6 | 0.7 | 5600 | 2230 | 600 | 18000 |
LSK8.0-0.7 | 8 | 0.7 | 5900 | 2450 | 600 | 20000 |
LSK10.0-0.7 | 10 | 0.7 | 6300 | 2640 | 700 | 22000 |
LSK12.0-0.7 | 12 | 0.7 | 6750 | 2840 | 800 | 24000 |
LSK16.0-0.7 | 16 | 0.7 | 7000 | 2840 | 900 | 28000 |
LSK20.0-0.7 | 20 | 0.7 | 7000 | 3040 | 1000 | 34000 |
LSK25.0-0.7 | 25 | 0.7 | 7200 | 3240 | 1100 | 42000 |
LSK30.0-0.7 | 30 | 0.7 | 9000 | 3650 | 1100 | 50000 |
QFK Exhaust Gas Thermal Oil Heater With Internal Bypass
type and specs | rated steam capacity(m2) | working pressure(Mpa) | engine power(KW) | dimensions(mm) | weight(kg) | |
H | A | |||||
QFK210-0.7 | 55 | 0.7 | ~1650 | 3800 | 1350 | 4500 |
QFK400-0.7 | 55 | 0.7 | ~6000 | 4200 | 1860 | 5000 |
QFK65-0.7 | 65 | 0.7 | ~2800 | 4000 | 1610 | 5500 |
QFK75-0.7 | 75 | 0.7 | ~3800 | 4000 | 1824 | 6000 |
QFK1000-0.7 | 120 | 0.7 | ~7200 | 4660 | 2242 | 9000 |
QFK1100-0.7 | 110 | 0.7 | ~8000 | 4460 | 2292 | 9000 |
QFK Exhaust Gas Thermal Oil Heater With External Bypass
type and specs | rated steam capacity(m2) | working pressure(Mpa) | engine power(KW) | dimensions(mm) | weight(kg) | ||
H | A | B1 | |||||
QFK15-0.5 | 15 | 0.5 | ~1200 | 2800 | 1310 | 1120 | 1700 |
QFK30-0.5 | 30 | 0.5 | ~1750 | 2800 | 1310 | 1340 | 2000 |
QFK36-0.5 | 36 | 0.5 | ~2500 | 2800 | 1600 | 1340 | 2500 |
QFK55-0.5 | 55 | 0.5 | ~3300 | 3380 | 1940 | 1480 | 3500 |
boiler onboard ship
More types of boilers with competitive price can be offered, please contact us for more details.