China (Mainland)
Deyuan
FA-SPYC
Rubber
Low Voltage
Marine
Copper
PVC
Galvanized Steel Wire
Wooden Drum and Container Shipment
15-30days
FA-SPYC Flame Retardant Marine Cable(JIS C 3410)
CABLE TYPE:
[FA-] SPYC SPYCY 0.6/1KV
[FA-] SPYCB SPYCBY 0.6/1KV
Marine Cable:
SPECIFICATION & STANDARDS
IEC 60288 IEC60092-376 IEC60092-351 IEC60092-359
IEC60332-1 IEC60332-3Cat.A
IEC61034 IEC 60754
Construction:
1. Conductor: tinned copper
2. Mica tape
3. Insulation: EPR
4. Core screen: Tinned copper wire braid
5. Tape
6. Inner sheath: PCP/CSP/PVC/PO (SHF1, SHF2)
7. Armored: tinned copper wire braid
(Galvanized steel wire braid)
8. Outer sheath: PVC/PO (SHF1, SHF2)
Flammability Features:
NA: Fire-resisting cable
NC/NSC: Fire-resisting cable halogen-free, low-smoke, low-toxicity.
Specifications:
Cores: 1, 2, 3, 4, 5, 7, 10, 12, 14, 16,19, 24, 27, 30, 33, 37.
Nominal Cross-section Areas: 1 mm2, 1.5mm2, 2.5mm2
Application:
The cable is intended for power, lighting and control system of shipboard and off-shore building.
Certificates:
CCS,LR,ABS,DNV,BV,GL,NK,RINA; 85
APPLICATION STANDARDS:
Design guard: JIS C 3410
Flame retardant: IEC60332-1 & IEC60332-3 CAT. A
Max. Conductor Temperature: 85 °C
Number of Conductor: 1Core
Size of Conductor (mm2): 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
For other cores and size of cable, please check other cable types or contact us.
The radius of bend for the installation of cables
Cable structure features | Over diameter of cable(D) | Minimum internal bending radius |
Metal braided armored | Any value | 6D |
Non-armored | D≤25 | 4D |
D>25 | 6D |
FA-SPYC Flame Retardant Marine Cable(JIS C 3410)
CABLE TYPE:
[FA-] SPYC SPYCY 0.6/1KV
[FA-] SPYCB SPYCBY 0.6/1KV
Marine Cable:
SPECIFICATION & STANDARDS
IEC 60288 IEC60092-376 IEC60092-351 IEC60092-359
IEC60332-1 IEC60332-3Cat.A
IEC61034 IEC 60754
Construction:
1. Conductor: tinned copper
2. Mica tape
3. Insulation: EPR
4. Core screen: Tinned copper wire braid
5. Tape
6. Inner sheath: PCP/CSP/PVC/PO (SHF1, SHF2)
7. Armored: tinned copper wire braid
(Galvanized steel wire braid)
8. Outer sheath: PVC/PO (SHF1, SHF2)
Flammability Features:
NA: Fire-resisting cable
NC/NSC: Fire-resisting cable halogen-free, low-smoke, low-toxicity.
Specifications:
Cores: 1, 2, 3, 4, 5, 7, 10, 12, 14, 16,19, 24, 27, 30, 33, 37.
Nominal Cross-section Areas: 1 mm2, 1.5mm2, 2.5mm2
Application:
The cable is intended for power, lighting and control system of shipboard and off-shore building.
Certificates:
CCS,LR,ABS,DNV,BV,GL,NK,RINA; 85
APPLICATION STANDARDS:
Design guard: JIS C 3410
Flame retardant: IEC60332-1 & IEC60332-3 CAT. A
Max. Conductor Temperature: 85 °C
Number of Conductor: 1Core
Size of Conductor (mm2): 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
For other cores and size of cable, please check other cable types or contact us.
The radius of bend for the installation of cables
Cable structure features | Over diameter of cable(D) | Minimum internal bending radius |
Metal braided armored | Any value | 6D |
Non-armored | D≤25 | 4D |
D>25 | 6D |